| 102/204/510 |
kg |
Maximum capacity (Emax) |
| C3 |
C1 |
(GP) |
|
Accuracy class according to OIML R60 |
| 3000 |
1000 |
n.a. |
|
Maximum number of verification intervals (nls) |
| Emax/10200 |
Emax/5100 |
n.a. |
|
Minimum load cell verification inteval |
| ± 0.0137 |
± 0.0275 |
± 0.0400 |
%R0/10°C |
Tempereture effect on minimum desd load output (TC0) |
| ± 0.0100 |
± 0.0160 |
± 0.0200 |
%R0/10°C |
Temperature effect om sensitivity (TCR0) |
| ± 0.0200 |
± 0.0300 |
± 0.0500 |
%R0 |
Combined error |
| ± 0.0166 |
± 0.0300 |
± 0.0400 |
%R0 |
Non-linearity |
| ± 0.0166 |
± 0.0300 |
± 0.0400 |
%R0 |
Hysteresis |
| ± 0.0166 |
± 0.0490 |
± 0.0600 |
%R0 |
Creep error (30 minutes) / DR |
| Emax/20400 |
n.a. |
n.a. |
|
Min.load cell verification interval (Vmin opt) |
| ± 0.0069 |
n.a. |
n.a. |
%R0/10°C |
Temp .effect on min.dead load output (TC0 opt) |
| 2 ± 10% |
mV/V |
Rated Output (R0) |
| ± 5 |
%R0 |
zero balance |
| 5-15 |
V |
Excitation voltage |
| 1100 ± 50 |
Ω |
Input resistance (RLc) |
| 100 ± 2 |
Ω |
Output resistance (R out) |
| ≥ 5000 |
MΩ |
Insulation resistance (100 V DC) |
| 200 |
%Emax |
Safe load limit (Elim) |
| 300 |
%Emax |
Ultimate load |
| -10~+40 |
°C |
compensated temperatue range |
| -40~+80(ATEX-40~+60) |
°C |
Operation temperature range |
| stainless steel 17-4 PH(1.4548) |
|
Load cell material |
| Aluminium |
|
Sealing |
| IP68 |
|
Protection according EN 60 529 |