| 7.5/15/22.5/30/40/50 |
7.5/15/55.5/30/40/50/100/150/300 |
t |
Maximum capacity (Emax) |
| 2%Emax |
Minimum dead load (Emin) |
| C4 |
C3MI8 |
C3 |
C1 |
(GP) |
|
Accuracy class according to OIML R60 |
| 4000 |
3000 |
1000 |
n.a. |
|
Maximum number of verification intervals(nls) |
| Emax/15 000 |
Emax/5000 |
n.a. |
|
Minimum load cell verification inteval |
| ±0.0093 |
±0.0280 |
±0.0400 |
%R0/10°C |
Temp.effect on minimum dead load output (TC0) |
| ±0.0080 |
±0.0100 |
±0.0160 |
±0.0200 |
%R0/10°C |
Temperature effect om sensitivity (TCR0) |
| ±0.0180 |
±0.0180 |
±0.0200 |
±0.0300 |
±0.0500 |
%R0 |
Combined error |
| ±0.0125 |
±0.0166 |
±0.0166 |
±0.0300 |
±0.0400 |
%R0 |
Non-linearity |
| ±0.0125 |
±0.0062 |
±0.0166 |
±0.0300 |
±0.0400 |
%R0 |
Hysteresis |
| ±0.0125 |
±0.0062 |
±0.0166 |
±0.0490 |
±0.0600 |
%R0 |
Creep error (30 minutes) / DR |
| n.a. |
n.a. |
Emax/1000 |
n.a. |
n.a. |
|
Min.load cell verificationinterval (Vmin opt) |
| n.a. |
n.a. |
±0.0140 |
n.a. |
n.a. |
%R0/10°C |
Temp .effect on min.dead load output(TC0 opt) |
| 2 ± 0.1 |
mV/V |
Rated Output (R0) |
| ± 5 |
%R0 |
zero balance |
| 5-15 |
V |
Excitation voltage |
| 1150 ± 50 |
Ω |
Input resistance (RLc) |
| 1000 ± 2 |
Ω |
Output resistance (R out) |
| ≥ 5000 |
MΩ |
Insulation resistance (100 V DC) |
| 200 |
%Emax |
Safe load limit (Elim) |
| 300 |
%Emax |
Ultimate load |
| 200 |
%Emax |
Safe side load |
| -10~+40 |
°C |
compensated temperatue range |
| -40~+80(ATEX-40~+60) |
°C |
Operation temperature range |
| stainless steel 17-4 PH(1.4548) |
|
Load cell material |
| cable entry seald by glass to metal header |
|
Sealing |
| IP68(up to 2 m water depth)/ IP69k |
|
Protection according EN 60 529 |