توضیحات
TECHNICAL PARAMETER
0.5/1/2.5/5 | 227/454/1134/2268/4536 | kg | Maximum capacity (Emax) | ||
C3 MI 6 | C3 | Accuracy class according to OIML R60 | |||
3000 | 3000 | n.a. | Maximum number of verification intervals (nls) | ||
Emax/11500 | n.a. | Minimum load cell verification inteval | |||
± 0.0122 | ± 0.0400 | %R0/10°C | Tempereture effect on minimum desd load output | ||
± 0.0100 | ± 0.0200 | %R0/10°C | Temperature effect om sensitivity (TCR0) | ||
± 0.0180 | ± 0.0200 | ± 0.0500 | %R0 | Combined error | |
± 0.0166 | ± 0.0166 | ± 0.0400 | %R0 | Non-linearity | |
± 0.0166 | ± 0.0166 | ± 0.0400 | %R0 | Hysteresis | |
± 0.0083 | ± 0.0166 | ± 0.0600 | %R0 | Creep error (30 minutes) / DR | |
2 ± 0.1% | mV/V | Rated Output (R0) | |||
± 5 | %R0 | zero balance | |||
5-15 | V | Excitation voltage | |||
1100 ± 50 | Ω | Input resistance (RLc) | |||
1000 ± 2 | Ω | Output resistance (R out) | |||
≥ 5000 | MΩ | Insulation resistance (100 V DC) | |||
200 | %Emax | Safe load limit (Elim) | |||
300 | %Emax | Ultimate load | |||
100 | %Emax | Safe side load | |||
-10~+40 | °C | compensated temperatue range | |||
-40~+80(ATEX-40~+60) | °C | Operation temperature range | |||
tool steel; painted | Load cell material | ||||
cable entry sealed by glass to metal header | Sealing | ||||
IP68(up to 2 m water depth) / IP69k | Protection according EN 60 529 |
Connection
Ref- | ref+ | shield | Sig – | Sig + | Exc- | Exc + |
Yellow | Red | White | Black | Green |