| 30/40/50 |
t |
Maximum capacity (Emax) |
| C4 |
C3 |
C1 |
(GP) |
|
Accuracy class according to OIML R60 |
| 4000 |
3000 |
1000 |
n.a. |
|
Maximum number of verification intervals (nls) |
| Emax/10 000 |
Emax/5000 |
n.a. |
|
Minimum load cell verification inteval |
| ±0.0093 |
± 0.0280 |
± 0.0400 |
%R0/10°C |
Tempereture effect on minimum desd load output (TC0) |
| ± 0.0080 |
± 0.0100 |
± 0.0160 |
± 0.0200 |
%R0/10°C |
Temperature effect om sensitivity (TCR0) |
| ± 0.0180 |
± 0.0200 |
± 0.0300 |
± 0.0500 |
%R0 |
Combined error |
| ± 0.0125 |
± 0.0166 |
± 0.0300 |
± 0.0400 |
%R0 |
Non-linearity |
| ± 0.0125 |
± 0.0166 |
± 0.0300 |
± 0.0400 |
%R0 |
Hysteresis |
| ± 0.0125 |
± 0.0166 |
± 0.0490 |
± 0.0600 |
%R0 |
Creep error (30 minutes) / DR |
| 200 000 ±200(±0.1%R0) |
counts |
Rated output (R0) |
| ± 2000(±1%R0) |
counts |
Zero balance |
| 9-12 |
V |
Excitation voltage |
| 40 |
mA |
Current consumption |
| Sigma-Delta ratiometric |
|
Convert type |
| 5 Hz(3 to 80 Hertz, factory configuration only) |
|
Conversion rate |
| 200 |
%Emax |
Safe load limit (Elim) |
| 300 |
%Emax |
Ultimate load |
| -10~+40 |
°C |
compensated temperatue range |
| -40~+60 |
°C |
Operation temperature range |
| stainless steel 17-4 PH(1.4548) |
|
Load cell material |
| cable entry seald by glass to metal header |
|
Sealing |
| IP68(up to2 m water depth)/IP69k |
|
Protection according EN 60 529 |